Adwest Technologies, Inc .Adwest Technologies' RETOX Dual Chamber RTO Oxidizer systems have been successfully utilized on hundreds of industrial VOC air pollution control applications since 1988. Because no two applications are ever alike, we...
H2O Engineering H2O Engineering, Inc. of San Luis Obispo, CA is a full-service resource for soil and groundwater remediation through in situ chemical oxidation (ISCO) and bioremediation equipment, specializing in the use of ozone sparge...
HORIBA, Ltd The HORIBA Group of worldwide companies provides an extensive array of instruments and systems for applications ranging from automotive R&D, process and environmental monitoring, in-vitro medical diagnostics,...
CDCTS-5000
The CDTCS-5000 is the ideal system for automated vehicle emissions testing. It controls and coordinates the test-cell equipment to meet worldwide emissions...
STARS Engine
With a wide range of user-friendly features, STARS can run the most complex of tests with a simple press of a button making your test operation effective...
VETS ONE
Test Request Computer (Windows-based operating system) to request and evaluate emission tests. The VETS ONE application running on this computer contains a...
LumaSense Technologies LumaSense Technologies is a global leader in providing temperature and gas sensing solutions to industrial, energy, medical and clean technology markets.The design and manufacture sensors for end-user and original...
Chemical caotegorization (or banding) of inherent toxicity and potency linked with defined engineering and work practice controls and personal protective equipment has become an integral component of assuring the health and safety of researchers and manufactruing personnel in the pharmaceutical industry.
The core of any good clinical supply chain system is a supply management system that addresses all of the nuances of clinical supplies. Although Clinical Supply Management is often considered a back-office business unit for a sponsor, it is almost always on the critical path of the drug development process. The efficient, accurate and timely delivery of material to the investigators is critical ...
Variable air volume (VAV) systems are often used to ehaust air from chemical fume hoods. VAV controls reduce the exhaust air flow in proportion to the actual need. Consequently the system uses less fan powe, and less energy is used to condition the rplacement air.
Unlike fume hoods, however, biosafety cabinets require a constant flow of air to contain contamination and to protect products in ...
Occupational exposure and alleged health effects situations are complex and contain several components which may include physical, psychological and emotional effects on workers potentially exposed or effected. A thorough investigation is required with an objective of both solving the problem technically and communicating the risk effectively. Risk communication techniques are a learned skill and ...
An Overview of Setting Occupational Exposure Limits (OELs) for Pharmaceuticals Robert H. Ku, Ph.D., CIH, Principal Toxicologist [Published in Chemical Health & Safety, January/February 2000]
Setting appropriate occupational exposure limits is an integral component in assuring the health and safety of workers
Introduction Occupational exposure limits (OELs) 1 for the protection of workers have ...
On the surface, providing a specified humidity and temperature for stability testing may appear easier to achieve than the 5% RH and 2C ICH guidelines would seem to indicate. The ability to control humidity at 2% does not mean that you are safely within the 5% RH tolerance dictated by ICH.
The ability to produce a recording, display, or printout that is within a specified tolerance may not be a ...
There are often problems implementing conventional methods of controlling particulate exposures during many pharmaceutical manufacturing processes. Pharmaceutical manufacturing processes tend to be less flexible than similar chemical manufacturing processes due to the high level of regulation within the industry (i.e., Food and Drug Administration (FDA)). In addition, because the products are ...
Chemical categorization (or banding) of inherent toxicity and potency linked with defined safe work environments including exposure controls has become an integral component of assuring the health and safety of research workers and manufacturing personnel in the pharmaceutical industry but is not a substitute for quantitative risk assessment in the workplace.
A database coupled to a statistical analysis program is an effective means for defining a control space, determining process capability of components, establishing specifications for components and drug product and potentially correlating leachable levels to component extractable levels.
This paper documents a solution provided by DMC to one of its customers in the form of a vision inspection and data acquisition system. DMC is an engineering consulting company that provides custom software solutions for its customers. For this project the customer is a company that operates chemical plating processes for metal products. In this solution, a “smart” digital camera is set up and ...